Free NS0-520 sample questions

Real questions from the Netapp Certified Implementation Engineer - San Ontap practice bank, with the correct answer and an explanation for each one. No junk, no filler.

Try them in the simulator Same questions, with study, timed and flashcard modes.

Showing 10 of 20 free sample questions.

Question 1Choose 2

A customer is migrating from a legacy SAN environment to ONTAP. They want to ensure their host bus adapters (HBAs), FC switch firmware, and guest OS versions are fully supported. Which two NetApp tools should be used to validate the complete I/O path? (Select TWO)

Question 2Choose one

True or False: When using Asymmetric Namespace Access (ANA) with NVMe/FC in ONTAP, all paths to a given namespace are reported to the host as 'Optimized/Active'.

Question 3Choose one

A financial institution uses SnapMirror Synchronous (SM-S) to protect a critical database LUN. During a disaster recovery test, the primary site goes offline. What is the state of the LUN on the secondary site, and what action is required to bring it online for host access?

Question 4Choose one

An administrator is provisioning a new 5 TB LUN for a VMware datastore. To optimize space savings, they want to use thin provisioning and enable deduplication. What is the correct sequence of operations in ONTAP?

Question 5Choose one

An administrator is investigating a performance issue where a Linux host connected via FC is experiencing intermittent high latency. The ONTAP cluster has four nodes. The administrator suspects the host is sending I/O over non-optimal paths. Which ONTAP CLI command would help verify the LUN's logical path and its physical location?

Question 6Choose one

A new iSCSI LIF is created on an ONTAP node, but the host initiator is unable to log in to the target portal. A packet capture on the host shows it is sending discovery requests, but no response is received from the storage. The LIF can be pinged from the host. What is the most likely cause of this issue?

Question 7Choose one

A new SAN implementation requires migrating LUNs from a third-party storage array to a new ONTAP cluster with minimal host-side disruption. The implementation engineer plans to use Foreign LUN Import (FLI). Which step is essential for the cutover phase of the FLI process?

Question 8Choose one

What is the primary function of a portset in an ONTAP FCP environment?

Question 9Choose one

You are configuring a new SVM for iSCSI access on a 2-node AFF A250 cluster. To ensure high availability and load balancing, what is the minimum number of iSCSI data LIFs that should be created for this SVM?

Question 10Choose one

When implementing NVMe/FC on an existing FC SAN fabric, which switch-level feature is a mandatory prerequisite for ONTAP integration?

10 more free samples are waiting

Create a free account to unlock the whole NS0-520 sample bank, or get full access to all 208 practice questions in the simulator.

Create account